Dimensions
Capacity
Control Panel
Sound Level
Modulation Rate
EfficiencyWith a 12-liter capacity, it provides maximum hot water efficiency with minimum size. Along with easy and safe usage, it ensures excellent performance with low energy consumption.
| TECHNICAL DATA | UNIT | WARMHAUS | |
| Gas type | (G20) | G31 | |
| Gas Supply Pressure | mbar | 20 | 37 |
| Gas Category | I2H I2H, I2E, I2E(S), I3P, II2E3P, II2E(S)3P, II2H3P, II2E+3P. | ||
| Rated Heat Load (Minimum) | kW | 10.0 | 10 |
| Rated Heat Load (Maximum) | kW | 23.5 | 23,5 |
| Rated Heat Power (Minimum) | kW | 8.90 | 8,95 |
| Rated Heat Power (Maximum) | kW | 20.7 | 20,6 |
| Efficiency (Minimum) | % | 89.2 | 89,5 |
| Efficiency (Maximum) | % | 88.1 | 87,62 |
| Gas Consumption (minimum) | m3/h | 1.03 | 0,4 |
| Gas Consumption (maximum) | m3/h | 2.43 | 0,959 |
| Nozzles | 85 | 50 | |
| NOx | Grade | 6 | 6 |
| NOx | mg/kWh | 37.7 | 26 |
| Hot water Load profile | Load Profile | L | |
| Seasonal Efficiency | % | 77 | |
| Seasonal Efficiency Class | Grade | A | |
| Minimum Water Flow | ℓ/min. | 3 | |
| Maximum Water Capacity (ΔT=25 °C) | ℓ/min. | 12 | |
| Sound Level | dB | 48 | |
| Water Pressure (max.) | bar | 10 | |
| Water Pressure (min.) | bar | 0.5 | |
| Setting Range | oC | 35-60 | |
| Power Supply | V AC | 230 V +10%;-15%, 50 Hz | |
| Electrical Protection Class | IPX4D | ||
| Electric Consumption | W | 20 - 30 | |
| Waste Gas Temperature (min.-max.) | oC | 110 - 190 | |
| Flue type | C12, C32 C42, C52, C62, C82, B22, B22P |
||
| Flue mass flow rate (min./max) | g/s | 9 / 13 | |
| Dimensions | mm | 638 x 336 x 242 | |
| Volume of Device | Liter | 51.9 | |
| Weight, Net | kg | 15 | |
| Weight, Gross | kg | 17 | |
| MAINTENANCE | |||